The CellaVision DM9600 is designed to automate and simplify the process of performing blood and body fluid differentials. The system leverages high-speed robotics and digital imaging to automatically locate and capture high-quality images of cells.

Description
CellaVision DM9600
When implemented together with supporting applications and software, the DM9600 becomes the engine of an automated and digital workflow for cell morphology, enabling laboratories to work smarter and perform better.
The DM9600 system is ideal for hematology labs with high-volume testing requirements:
- Loading capacity: 96 slides, with continuous feed
- Throughput: Approximately 30 slides / h*
How it works
- The system scans and reads the slide barcode and queries the Laboratory Information System for patient demographics and order data.
- The slide is automatically placed under the microscope and the monolayer is identified, cells are located and high-quality cell images captured.
- When processing is complete, the Medical Technologist is presented with pre-classified white blood cells and pre-characterized red blood cells for review and verification
Features
- Automatically captures digital images of cells from peripheral blood smears and body fluid preparations
- Automates the analysis of WBCs, RBCs and body fluids and provides an overview of the feathered edge
- Loading capacity of 96 slides, with mechanism for continuous feed
- Approximately 30 slides throughput per hour*
- Creates digital scan of pre-defined area of any interesting specimen
Important information
Please note that this product may not be available in all markets.
*Processing time may vary depending on smear quality, WBC concentration and number of non-WBCs
Information Request
Want to learn more about our product concept, request a demonstration, or just get in touch with CellaVision or your local CellaVision distributor? Click here.
Technical specifications
- Requires barcode labeled slides with clipped/ round corners
-
Slides are loaded into magazines with the capacity of 12 slides. Fits eight magazines.
-
Analyzes slides with blood smears and body fluids either batched in dedicated magazines or mixed when interfaced to a LIS
- Automatic dispensing
- Easy replacement of oil pack
Cell location accuracy test for the verification of the hardware and stain quality
LAN
- Primary storage: On local hard drive up to 4,000 slides (20 GB)
-
Secondary storage: Unlimited when transferred to external storage media
Laser/inkjet printers supported by Windows
- Bi-directional LIS support, ASTM
- Ethernet 10/100 Mbps
- Multiple CellaVision DM analyzers can share a database
- Slide Scanning Unit
- CellaVision DM Software
- System Computer with Windows
- Voltage input: 100 to 240 VAC
Current input:
- System computer: 1.4 to 0.7 A
- Slide scanning unit: 0.6 to 0.3 A
CE, 510(k)
- 580 × 560 × 790 mm
- 22.8 × 22 × 31,1 inches
93 kg / 205 lbs
Peripheral Blood:
- Up to 30 slides/h for complete differential (100 WBC+RBC+PLT)
Digital Slides:
- Up to 20 slides/h for 10 × 10 mm in 10x
- Up to 1,5 slides/h for 10 × 10 mm in 10x + 50x
Body Fluids (based on 6 mm sample area):
- Up to 15 slides/h for differential (100 WBCs + 10x)
- Up to 3 slides/h for differential (100 WBCs + 10x + 50x)
* Processing time may vary depending on smear quality, WBC concentration and number of non-WBCs. Specifications are subject to change without notice. This product may not be available in all markets.
- CellaVision® Advanced RBC Application • CellaVision® Body Fluid Application
- CellaVision® Remote Review Software • CellaVision® Server Software
- CellaVision® Proficiency Software
- CellaVision Immersion Oil Pack
- Barcode labeled slide magazines • QC barcode labels
- Label printer kit
CellaVision DM9600
When implemented together with supporting applications and software, the DM9600 becomes the engine of an automated and digital workflow for cell morphology, enabling laboratories to work smarter and perform better.
The DM9600 system is ideal for hematology labs with high-volume testing requirements:
- Loading capacity: 96 slides, with continuous feed
- Throughput: Approximately 30 slides / h*
How it works
- The system scans and reads the slide barcode and queries the Laboratory Information System for patient demographics and order data.
- The slide is automatically placed under the microscope and the monolayer is identified, cells are located and high-quality cell images captured.
- When processing is complete, the Medical Technologist is presented with pre-classified white blood cells and pre-characterized red blood cells for review and verification
Features
- Automatically captures digital images of cells from peripheral blood smears and body fluid preparations
- Automates the analysis of WBCs, RBCs and body fluids and provides an overview of the feathered edge
- Loading capacity of 96 slides, with mechanism for continuous feed
- Approximately 30 slides throughput per hour*
- Creates digital scan of pre-defined area of any interesting specimen
Important information
Please note that this product may not be available in all markets.
*Processing time may vary depending on smear quality, WBC concentration and number of non-WBCs
Information Request
Want to learn more about our product concept, request a demonstration, or just get in touch with CellaVision or your local CellaVision distributor? Click here.
- Requires barcode labeled slides with clipped/ round corners
-
Slides are loaded into magazines with the capacity of 12 slides. Fits eight magazines.
-
Analyzes slides with blood smears and body fluids either batched in dedicated magazines or mixed when interfaced to a LIS
- Automatic dispensing
- Easy replacement of oil pack
Cell location accuracy test for the verification of the hardware and stain quality
LAN
- Primary storage: On local hard drive up to 4,000 slides (20 GB)
-
Secondary storage: Unlimited when transferred to external storage media
Laser/inkjet printers supported by Windows
- Bi-directional LIS support, ASTM
- Ethernet 10/100 Mbps
- Multiple CellaVision DM analyzers can share a database
- Slide Scanning Unit
- CellaVision DM Software
- System Computer with Windows
- Voltage input: 100 to 240 VAC
Current input:
- System computer: 1.4 to 0.7 A
- Slide scanning unit: 0.6 to 0.3 A
CE, 510(k)
- 580 × 560 × 790 mm
- 22.8 × 22 × 31,1 inches
93 kg / 205 lbs
Peripheral Blood:
- Up to 30 slides/h for complete differential (100 WBC+RBC+PLT)
Digital Slides:
- Up to 20 slides/h for 10 × 10 mm in 10x
- Up to 1,5 slides/h for 10 × 10 mm in 10x + 50x
Body Fluids (based on 6 mm sample area):
- Up to 15 slides/h for differential (100 WBCs + 10x)
- Up to 3 slides/h for differential (100 WBCs + 10x + 50x)
* Processing time may vary depending on smear quality, WBC concentration and number of non-WBCs. Specifications are subject to change without notice. This product may not be available in all markets.
- CellaVision® Advanced RBC Application • CellaVision® Body Fluid Application
- CellaVision® Remote Review Software • CellaVision® Server Software
- CellaVision® Proficiency Software
- CellaVision Immersion Oil Pack
- Barcode labeled slide magazines • QC barcode labels
- Label printer kit
In need of more information?
Would you like to learn more about our product concept, request a demonstration, or get in touch with CellaVision or your local CellaVision distributor?