Global Evidence for CellaVision

This collection highlights peer-reviewed, independent studies that evaluate the performance, reliability and clinical impact of CellaVision instruments.

Conducted by laboratories and healthcare organizations around the world, this body of research provides a robust evidence base for using CellaVision digital cell morphology in modern hematology practice.

Bibliography

Author:
Zhao Yue, McCracken Jenna, Wang Endi
Journal, year:
International Journal of Laboratory Hematology, 2022

Summary: In this case report, the CellaVision Digital Morphology System was used during peripheral blood smear review to capture rare neutrophils containing yeast-like inclusions that were partly obscured by toxic granulation. The system initially preclassified these cells into non-specific buckets (“unidentified/other”) and even labeled a cluster of free yeasts as “artifact,” but crucially it still flagged and presented them for hematopathologist review. On the CellaVision images, about 2–4% of neutrophils showed ovoid organisms with crescentic nuclei and capsule-like halos, morphologically suggestive of Histoplasma capsulatum, which prompted confirmatory antigen/serology testing and culture. The main finding is that CellaVision-enabled digital review helped detect disseminated histoplasmosis directly from blood smear morphology, a pattern that can be missed on manual review, enabling timely antifungal treatment.

Instrument:
-
Keyword:
Histoplasmosis, WBC
Author:
Rosetti Marco, Di Carlo Claudia, Poletti Giovanni, Massari Evita, Monti Marta, Romano Giuseppe, Libri Virginia, Olivieri Melania, Polli Valentina, Baldrati Luca, Valenti Stefania, Fasano Tommaso
Journal, year:
Journal of Clinical Pathology, 2022

Summary: In this correspondence, the lab describes how they use the Sysmex DI-60 with CellaVision software for routine digital blood-smear review across a hub-and-spoke network, with remote assessment enabled. The DI-60/CellaVision system was set to automatic preclassification of 200 WBCs into 14 leukocyte subtypes plus 5 “non-leukocyte” categories (erythroblasts, giant platelets, platelet aggregates, smudge cells, artefacts). The key point is that the authors systematically review not only WBC categories but also the “non-leukocyte” buckets, because important pathology can be hidden there. By carefully checking sections like “thrombocyte aggregation” and “artefact,” they unexpectedly detected clinically crucial findings—e.g., Plasmodium-parasitized RBCs, bacteria phagocytosed by neutrophils and free cocci (sepsis), microfilaria, fungal elements including Fusarium and Candida spores, and cryoglobulins mixed with platelet clumps—often enabling earlier diagnosis and faster clinical action. Their conclusion is that digital morphology can surface rare patterns outside the main WBC sort, but expert review of all CellaVision categories remains essential to avoid missing these “hidden” signals.

Instrument:
DI-60
Keyword:
Detection of pathological features
Author:
Moreno-Castaño Ana Belén, Diaz-Ricart Maribel, Escolar Ginés, García Estefanía, Mañú-Pereira María del Mar, Idrizovic Amira, Matute Mónica, Molina Angel, Faneca Joana, Merino Anna
Journal, year:
International Journal of Laboratory Hematology, 2022

Summary: In this Letter to the Editor on Southeast Asian ovalocytosis (SAO) in a critically ill COVID-19 patient, the authors used CellaVision DM96 to perform the peripheral blood smear morphology review. The DM96 digital analysis revealed the characteristic red-cell pattern—numerous macro-ovalocytes, stomato-ovalocytes, and stomatocytes with longitudinal/transverse “stomas,” sometimes multiple per cell, which was distinctive enough to raise the diagnosis of SAO. Finding SAO on the DM96 smear prompted confirmatory testing, including molecular demonstration of the SLC4A1 deletion and ektacytometry. The main takeaway is that DM96-enabled digital morphology was the key trigger for diagnosing an otherwise unsuspected congenital RBC membrane disorder, and the authors suggest SAO plus COVID-19 may synergistically worsen RBC deformability and potentially increase thrombotic risk.

Instrument:
DM96
Keyword:
COVID19, ovalocytosis, RBC
Author:
Fuji Shigeo, Yasunaga Jun Ichirou, Watanabe Eri, Matsuoka Masao, Uchimaru Kaoru, Ishikawa Jun
Journal, year:
Haematologica, 2022

Summary: In this case report, the authors used a CellaVision DC-1 to obtain and document digital peripheral-blood images of abnormal lymphocytes that appeared after cord-blood transplantation in patients with Adult T-cell leukemia-lymphoma (ATL). The CellaVision images provided clear morphology evidence of ATL-like lymphocytes in the blood and helped trigger further diagnostic work-up when relapse was suspected. On deeper analysis (flow cytometry, chimerism testing, and inverse PCR), they found the abnormal cells were donor-derived and polyclonal HTLV-1–infected T cells, not true recurrent adult T-cell leukemia/lymphoma. The main conclusion is that this represented pseudo-progression after transplant, and that when abnormal lymphocytes are detected post-HCT, clinicians should assess chimerism/clonality before assuming relapse—even if morphology on CellaVision looks ATL-like.

Instrument:
DC-1
Keyword:
T-cell leukemia
Author:
Allehebi Ziyad O., Khan Farhan M., Robbins Mark, Simms Elizabeth, Xiang Richard, Shawwa Allam, Lindsay L. Robbin, Dibernardo Antonia, d'Entremont Clarice, Crowell Alex, LeBlanc Jason J., Haldane David J.
Journal, year:
Emerging Infectious Diseases, 2022

Summary: In this article on a locally acquired babesiosis case, CellaVision was used to capture and display abnormal cells on the peripheral blood smear. The key diagnostic images of Babesia microti on the Wright-stained smear were shown in Figure 1; panels A and B are conventional Wright’s-stain views, while panel C was specifically captured and displayed using the CellaVision DM96 system together with CellaVision Remote Review Software v6.0.1. So, CellaVision’s role here was as the digital microscopy/remote review platform that documented the characteristic intra-erythrocytic ring forms and merozoites (including the Maltese-cross tetrad), supporting rapid recognition of babesiosis before PCR confirmation.

Instrument:
DM96
Keyword:
Babesiosis, RBC, remote-review, lyme disease, anaplasmosis
Author:
Nafría Jiménez Beatriz, Oliveros Conejero Raquel
Journal, year:
Advances in Laboratory Medicine, 2022

Summary: In this IgE multiple myeloma case report, CellaVision was used for peripheral blood morphology review as part of the initial hematology workup. After the CBC was run on a Sysmex XN-9100, the authors assessed the blood smear with CellaVision digital microscopy, which documented that the white cell differential had no significant abnormalities or circulating plasma cells, while the red-cell series showed rouleaux formation. That smear finding supported the suspicion of a monoclonal gammopathy and complemented the protein studies (capillary electrophoresis and immunofixation) that ultimately identified an IgE-kappa monoclonal component. In short, CellaVision served as the digital morphology tool to verify blood-film features (notably rouleaux and absence of plasma cells) within the diagnostic pathway of this rare myeloma subtype.

Instrument:
-
Keyword:
IgE, multiple myeloma
Author:
Lucis Riccardo, Poz Donatella, Poletto Monica, Puzzolante Liliana, Sartor Assunta, Curcio Francesco
Journal, year:
Clinical Chemistry and Laboratory Medicine, 2022

Summary: In this Letter to the Editor, CellaVision DM9600 was used as the digital morphology step that enabled early recognition of candidemia. The lab’s routine CBC on a Beckman Coulter DxH 800 showed abnormal scatterplot “clouds” suggestive of fungi, so a peripheral blood smear was made and then reviewed on a CellaVision DM9600 (alongside a manual Nikon microscope). On the DM9600 images, they directly observed yeast with budding forms and pseudohyphae, both extracellularly and phagocytosed inside neutrophils, which allowed them to alert clinicians immediately and trigger confirmatory fungal blood cultures. Culture later identified Candida parapsilosis, and targeted antifungal therapy was started days earlier than it otherwise would have been, leading to clinical improvement and discharge. The main message is that DM9600-based smear review can catch circulating fungi very early when automated analyzers raise suspicion, supporting faster diagnosis and treatment of severe nosocomial fungal infections.

Instrument:
DM9600
Keyword:
Candida parapsilosis, dm-9600, manual microscopy, yeast
Author:
Chen Xueyan, Luo Faxin, Zhu Rong
Journal, year:
International Journal of Laboratory Hematology, 2022

Summary: In this case report, the authors used a DI-60 analyzer to capture and document high-magnification digital images of the patient’s peripheral blood smear. The DI-60 images clearly showed numerous yeast-like organisms with central septa both inside neutrophils and extracellularly, which allowed the laboratory to make a rapid presumptive diagnosis of disseminated Talaromyces marneffei infection directly from the smear. This DI-60-supported diagnosis was then confirmed by blood culture. The main takeaway is that digital smear review on DI-60 enabled early recognition of a life-threatening opportunistic fungal infection in an AIDS patient, highlighting the value of careful peripheral smear examination for fungi in septic HIV cases.

Instrument:
DI-60
Keyword:
Talaromycosis, WBC
Author:
Zhang Yiting, Zhang Lixia
Journal, year:
International Journal of Laboratory Hematology, 2022

Summary: In this case report, the authors used the DI-60 to digitally identify and document peripheral blood smear morphology in a patient with suspected hemorrhagic fever with renal syndrome (HFRS). The DI-60 images showed left-shifted neutrophils with reactive changes, reactive plasmacytoid lymphocytes (some binucleated), and increased smudge cells, which are all identified by the DI-60. The main finding was that this morphology—together with CBC abnormalities (high WBC, severe thrombocytopenia) and a characteristic cell counter scattergram—strongly pointed to hantavirus infection/HFRS, later confirmed by positive hantavirus IgM/IgG.

Instrument:
DI-60
Keyword:
WBC, Hemmorrhagic fever, CBC
Author:
Karlsson Linda Katharina, Mottelson Mathis Nygaard, Helby Jens, Petersen Jesper, Glenthøj Andreas
Journal, year:
Leukemia Research Reports, 2022

Summary: In the article, the authors used a CellaVision DM1200 analyzer to digitally capture peripheral blood smear images. These digital images helped confirm abnormal erytrocyte morphology when earlier functional tests were equivocal, prompting further targeted genetic workup. The main finding was a rare case of acquired spherocytosis due to a somatic SPTB mutation occurring alongside an MDS-associated U2AF1 mutation, with the latter likely reflecting clonal hematopoiesis rather than causing the hemolysis. Clinically, the patient improved rapidly after splenectomy, with hemoglobin and bilirubin normalizing, supporting that the spherocytosis (not MDS) drove the anemia.

Instrument:
DM1200
Keyword:
RBC, Spherocytosis
Author:
Rosetti Marco, De la Salle Barbara, Farneti Giorgia, Clementoni Alice, Poletti Giovanni, Dorizzi Romolo M.
Journal, year:
Annals of Hematology, 2022

Summary: In this article, they are using CellaVision digital morphology software to evaluate a UKNEQAS external quality assessment (EQA) peripheral blood film, alongside conventional microscopy. They emphasize that unlike manual microscopy—where operators choose fields subjectively—CellaVision automatically selects key areas and requires the reviewer to systematically examine WBC, RBC, and platelet image sets, which can reduce “attention drift” toward only one abnormality. In the featured EQA case (acute leukemia plus sickle cell disease), most microscope users correctly saw blasts but missed sickle cells; by contrast, the CellaVision RBC screen made sickle and boat-shaped cells easy to spot, so their lab detected the additional diagnosis before the official UKNEQAS report. The main point is that CellaVision added diagnostic value in EQA review by preventing important RBC morphology from being masked by striking WBC findings, supporting broader, more reliable smear assessment.

Instrument:
-
Keyword:
blast detection, sickle cell disease, UKNEQAS
Author:
Kweon Oh Joo, Lim Yong Kwan, Lee Mi Kyung, Kim Hye Ryoun
Journal, year:
PLoS ONE, 2022

Summary: In this research article, the authors used the Sysmex DI-60 digital cell imaging analyzer to automatically scan peripheral blood smears, capture cell images, and perform two tasks: pre-characterization of RBC morphology and pre-classification of WBC differentials (200 cells/slide), with technologists then verifying/reclassifying results before reporting. They evaluated DI-60 on 822 routine smears, directly comparing its outputs to manual light-microscope review and also measuring total assay time versus hands-on verification time. The main findings were that the DI-60 showed acceptable performance on normal samples and good accuracy for some RBC features (polychromasia, target cells, ovalocytes), but it struggled with several abnormalities—most notably very low specificity for schistocytes (many false positives) and weaker performance for atypical lymphocytes, basophils, and some immature cells unless carefully verified. Even though DI-60’s total run time was longer than manual review, the hands-on time was ~144 seconds per slide shorter, indicating a real workflow-efficiency benefit when used with expert verification, especially in high-volume labs.

Instrument:
DI-60
Keyword:
Manual microscopy, RBC, TAT, WBC
Author:
Da Rin Giorgio, Seghezzi Michela, Padoan Andrea, Pajola Rachele, Bengiamo Anna, Di Fabio Anna Maria, Dima Francesco, Fanelli Alessandra, Francione Sara, Germagnoli Luca, Lorubbio Maria, Marzoni Alessandro, Pipitone Silvia, Rolla Roberta, Bagorria Vaca Mar
Journal, year:
International Journal of Laboratory Hematology, 2022

Summary: In this article, CellaVision instruments were evaluated as part of a multicenter assessment of digital morphology performance. Seven Italian labs received standardized May–Grünwald–Giemsa peripheral blood smears and analyzed them both by manual optical microscopy (the reference method) and by automated image-processing systems, specifically either the Sysmex DI-60 or the CellaVision DM96 running CellaVision DM Software. The CellaVision analyzers performed automated slide scanning and pre-classification of leukocytes into standard WBC categories, after which skilled morphologists reviewed and reclassified cells as needed; results from pre-classification and post-reclassification were compared to manual differentials. The main findings were that digital morphology systems can improve efficiency and objectivity, especially when extended counts are needed for rare cells, but variability remains for low-frequency cell types; neutrophil counts met desirable imprecision targets, while several other classes (e.g., blasts, basophils, NRBCs) showed poorer reproducibility across labs. Importantly, post-reclassification digital review was faster than manual microscopy (about 191 s vs 326 s per slide), so the authors conclude that digital systems such as CellaVision analyzers are valuable for saving time and enabling larger cell counts, which in turn can reduce statistical imprecision in routine morphology work.

Instrument:
DI-60, DM96
Keyword:
Inter laboratory precision, variability, manual microscopy, multicentric evaluation, variability-study, WBC
Author:
Nakamura Iori, Ida Haruhi, Yabuta Mayu, Kashiwa Wataru, Tsukamoto Maho, Sato Shigeki, Ota Syuichi, Kobayashi Naoki, Masauzi Hiromi, Okada Kazunori, Kaga Sanae, Miwa Keiko, Kanai Hiroshi, Masauzi Nobuo
Journal, year:
Scientific Reports, 2022

Summary: In this study, the authors used CellaVision DM96 in digital slide mode as the image-capture platform for bone marrow smears. They stained 43 bone-marrow films with May–Grünwald Giemsa, scanned them on DM96, and then selected well-focused microscopic fields (901×823 px) from the digital slides; these fields were cropped into 704×704 images and further segmented into single-cell crops to build a large dataset for deep-learning training and testing. The main finding was that semi-supervised learning can greatly expand labeled training data for bone-marrow cell classification, and that the combined method (confirmed self-training + active learning) performed best. After 25 rounds, CST+AL increased training images to ~47,843 and achieved the highest test accuracy (~0.976, with mean recall/precision ~0.976), outperforming either method alone. Errors mainly occurred among closely related granulocyte maturation stages (metamyelocytes, band neutrophils, segmented neutrophils), suggesting these are inherently harder to separate for both humans and AI.

Instrument:
DM96
Keyword:
Bone-marrow, digital-slide-mode, AI
Author:
Roland Kristine, Yakimec Jim, Markin Todd, Chan Geoffrey, Hudoba Monika
Journal, year:
Journal of Pathology Informatics, 2022

Summary: In this article, the authors describes an solution for implementing a costumized middelware. They used a DI-60 analyzer as part of their routine CBC/CBCD workflow together with Sysmex XN9000 analyzers, all connected through Data Innovations Instrument Manager middleware. The DI-60 supplied automated digital differentials and morphology images when slides were generated or when middleware rules flagged samples for microscopic review, effectively acting as the lab’s digital microscopy step within a largely paperless, rules-driven process. While the articles main focus is middleware, the DI-60 is the CellaVision instrument enabling the digital slide review that the rules either trigger, suppress, or streamline. The authors report that this integrated system achieved very high autoverification rates and reduced unnecessary slide work, showing how DI-60-based digital morphology fits into a modern, efficiency-optimized hematology workflow.

Instrument:
DI-60
Keyword:
Middleware-implementation, customized middleware
Author:
Ivady Gergely, Barath Sandor, Szaraz-Szeles Marianna, Szabo Kurti-G, Kovacs Kinga, Petruska Edina, Hevessy Zsuzsanna
Journal, year:
Annals of Clinical & Laboratory Science, 2022

Summary: In this study, CellaVision images were used as a morphological reference method for body-fluid differentials. Cytospin slides from cerebrospinal and ascitic fluids were scanned on a DM96 slide scanning unit running the CellaVision DM1200 Body Fluid Application, which preclassified 200 nucleated cells per sample. Two experienced technologists then manually reviewed and corrected these preclassifications, and the resulting mononuclear (MN%) and polymorphonuclear (PMN%) proportions were calculated. The aim was to determine how well instrumental body-fluid differentials correlate with morphology by comparing Sysmex XN BF-mode results against conventional optical microscopy, multicolor flow cytometry, and CellaVision digital differentials in tumor-free fluids. The main finding was strong agreement across methods: CellaVision MN% and PMN% closely matched manual microscopy and flow cytometry with high correlations and only small biases, leading the authors to conclude that instrumental BF differentials are reliable when malignant cells are absent and that CellaVision can effectively support or replace manual microscopy in routine practice, including for remote validation and as a reflex tool when analyzer flags suggest atypical cells.

Instrument:
DM96
Keyword:
Body-Fluid, comparison, evaluation, manual microscopy, WBC
Author:
La Sala Lucia, Gandini Sara, Bruno Antonino, Allevi Raffaele, Gallazzi Matteo, Senesi Pamela, Palano Maria Teresa, Meregalli Paola, Longhi Ermanno, Sommese Carmen, Luzi Livio, Trabucchi Emilio
Journal, year:
Frontiers in Immunology, 2022

Summary: In this research study, CellaVision DM96 was used as the digital morphology platform for reviewing peripheral blood smears during a vaccine follow-up study. Alongside CBC measurements on a Sysmex XN-9000, the authors examined whole-blood smears with the CellaVision DM96 Digital Cell Morphology System to assess morphological changes over time after Pfizer BNT162b2 vaccination. The DM96 review supported their hematology findings by documenting low-frequency anomalous/atypical lymphocyte forms (including plasmacytoid variants) that increased after the first dose and then declined after the booster, helping connect routine blood-film morphology with the evolving immune response.

Instrument:
DM96
Keyword:
COVID19 immunization
Author:
Kubik Thane, Hou Mary, Traverse Tammie, Lareau Mireille, Jenei Veronika, Oberding Lisa, Pillai Dylan R., Gillrie Mark, Suryanarayan Deepa, Sidhu Davinder Singh, Vergara-Lluri Maria, Nakashima Megan O., Mahe Etienne
Journal, year:
Archives of Pathology and Laboratory Medicine, 2022

Summary: In this observational research article on hospitalized COVID-19 patients, the authors used a CellaVision DC-1 digital morphology analyzer to scan peripheral blood smears and generate automated 500-cell differentials with preclassification, which were then manually verified by hematopathologists; atypical plasmacytoid/immunoblastic lymphocytes (“covidocytes”) were counted as a distinct category. The smear morphology data from the DC-1 were combined with routine lab values to look for outcome-predictive patterns. The main findings were that COVID-19 patients showed reproducible peripheral-smear abnormalities, including frequent covidocytes, smudge cells, and platelet aggregates, and that a simple risk-stratification decision tree using RBC count, creatinine, urea, and covidocyte percentage predicted critical outcomes about as well as WHO clinical severity scoring or the neutrophil-to-lymphocyte ratio. The authors conclude that incorporating digital blood-morphology assessment (enabled by CellaVision DC-1) adds clinical value for triage and prognostication in hospitalized COVID-19.

Instrument:
DC-1
Keyword:
COVID19, RBC, remote review, WBC
Author:
Drumheller Bradley, Gebre Kirubel, Lockhart Brian, Margolskee Elizabeth, Obstfeld Amrom, Paessler Michele, Pillai Vinodh
Journal, year:
International Journal of Laboratory Hematology, 2022

Summary: In this article, CellaVision was used to digitally image and archive Wright–Giemsa–stained peripheral blood smears from patients before and after various CAR-T therapies. The smears were scanned on a CellaVision DM1200 and analyzed with CellaVision’s peripheral blood smear software, which automatically sorted WBCs into 18 categories; the authors then focused on the lymphocyte and atypical-lymphocyte image groups and manually reviewed the archived images over multiple days post-infusion. Using these serial CellaVision images, they discovered a distinct, time-ordered sequence of three atypical lymphocyte morphologies (early, mid, late) that appeared after CAR-T infusion in responders and tracked the expansion/contracting phases of CAR-T cells. This characteristic morphologic progression was largely absent in non-responders and in transplant/donor-lymphocyte controls, supporting that the digital morphology readout can serve as a practical surrogate for CAR-T expansion and early response assessment.

Instrument:
DM1200
Keyword:
Atypical lymphocyte,CART-cell therapy, leukaemia, llymphoma, multiple-myeloma, WBC
Author:
Gupta Saurabh Kumar, Gohil Dievya, Panigrahi Girish Ch, Vaykar Swati, Rane Pallavi, Chavan Preeti, Gota Vikram
Journal, year:
Drug Metabolism and Personalized Therapy, 2022

Summary: In this short communication, the authors used a CellaVision analyzer as one of three automated systems to perform differential counts of lymphocytes and neutrophils in mouse blood, and they compared those results against manual microscopic counting as the gold standard. Slides were prepared on an automated slide maker, then CellaVision analyzer was run per manufacturer instructions on small-volume mouse blood samples, enabling digital morphology–based counting alongside ADVIA 2120i and Horiba Yumizen H2500. The main finding was that CellaVision showed the closest agreement with manual counts for both lymphocytes (low bias ~4.75) and neutrophils (bias ~0.68), whereas ADVIA agreed only for lymphocytes and Horiba agreed for neither cell type. Based on these Bland–Altman and Passing–Bablok comparisons, the authors concluded that CellaVision can reliably be used for neutrophil and lymphocyte differentials in preclinical mouse studies, with the added practical advantage of requiring very small blood volumes.

Instrument:
-
Keyword:
Gupta Saurabh Kumar, Gohil Dievya, Panigrahi Girish Ch, Vaykar Swati, Rane Pallavi, Chavan Preeti, Gota Vikram
Author:
Drumheller Bradley, Gebre Kirubel, Lockhart Brian, Margolskee Elizabeth, Obstfeld Amrom, Paessler Michele, Pillai Vinodh
Journal, year:
American Journal of Biomedical Sciences, 2022

Summary: In this paper, CellaVision is used as the source of the image dataset for training and evaluating the model. The authors worked with 10,299 individual white blood cell images acquired using a CellaVision DM96 analyzer in the core lab at Hospital Clinic of Barcelona, with cells annotated by expert clinical pathologists. They then trained a convolutional neural network with data augmentation on these CellaVision images to classify five WBC subtypes (neutrophils, eosinophils, basophils, lymphocytes, monocytes). Using this CellaVision-derived dataset, they achieved about 96% average classification accuracy, concluding that automated WBC classification from DM96 images can support faster, safer, and more consistent hematology diagnostics.

Instrument:
DM1200
Keyword:
Atypical lymphocyte,CART-cell therapy, leukaemia, llymphoma, multiple-myeloma, WBC
Author:
In this article the aim was to do a broad, high-quality comparison of routine CSF markers of neuroinflammation and blood–brain barrier (BBB) dysfunction in people with recent-onset psychotic disorders versus matched healthy controls. A CellaVision DM96 wa
Journal, year:
Schizophrenia Bulletin, 2022

Summary: In this article the aim was to do a broad, high-quality comparison of routine CSF markers of neuroinflammation and blood–brain barrier (BBB) dysfunction in people with recent-onset psychotic disorders versus matched healthy controls. A CellaVision DM96 was used specifically for differential counting and classification of cells in cerebrospinal fluid (CSF). After CSF and blood cell counts were run on a Sysmex XN9000, the CSF cell type distribution was analyzed using a DM96, with lab staff blinded to patient/control status. This DM96-based CSF differential supported the study’s neuroinflammation/BBB biomarker outcomes by providing standardized, reviewable CSF cytology alongside the routine CSF WBC measures. They found no significant shift in overall CSF cell-type percentages between patients with recent-onset psychosis and healthy controls (e.g., lymphocytes and macrophages proportions were similar). However, alongside this stable cell-type distribution, the study still detected signs of a subgroup-level immune/BBB signal: more patients had mildly elevated CSF WBCs and patients showed higher BBB permeability markers.

Instrument:
DM96
Keyword:
Body-Fluid, CSF, XN9000
Author:
Wettin Nils, Drogies Tim, Kühnapfel Andreas, Isermann Berend, Thome Ulrich Herbert
Journal, year:
Journal of Clinical Medicine, 2022

Summary: In this study, CellaVision was used for the manual white-blood-cell differential: experienced technicians reviewed May-Grünwald-Giemsa–stained neonatal blood smears on a CellaVision DM96 analyser, which automatically imaged and presented cells until 100 leukocytes were classified per smear. The DM96-based counts were then compared with automated Sysmex XN-9000 results to evaluate how well automated immature-granulocyte metrics diagnose neonatal infection.

Instrument:
DM96
Keyword:
WBC, Newborn
Author:
Merino Anna, Vlagea Alexandru, Molina Angel, Egri Natalia, Laguna Javier, Barrera Kevin, Boldú Laura, Acevedo Andrea, Díaz-Pavón Mar, Sibina Francesc, Bascón Francisca, Sibila Oriol, Juan Manel, Rodellar José
Journal, year:
Journal of Clinical Pathology, 2022

Summary: In this article the authors investigated whether COVID-19 patients with reactive lymphocytes (COVID-19 RL) show clinical or biological characteristics linked to disease outcome. In addition, they also aimed to develop an automatic, objective system to recognize these COVID-19 reactive lymphocytes on blood smears, and to study their immunophenotype to understand their role in patient prognosis. Peripheral blood smears from COVID-19 patients were stained and then digitally imaged using the CellaVision DM96 system. The DM96 provided standardized cell images that pathologists reviewed to identify atypical “COVID-19 reactive lymphocytes,” and those same DM96 images formed the dataset for training and testing their convolutional-neural-network classifier. In short, CellaVision was the image-capture platform enabling both morphological assessment and the AI-based automatic recognition used in the study.

Instrument:
DM96
Keyword:
COVID19, Reactive lymphocyte, WBC
Author:
Cooke Colin L., Kim Kanghyun, Xu Shiqi, Chaware Amey, Yao Xing, Yang Xi, Neff Jadee, Pittman Patricia, McCall Chad, Glass Carolyn, Jiang Xiaoyin Sara, Horstmeyer Roarke
Journal, year:
PLOS Digital Health, 2022

Summary: The study aimed to evaluate whether high-resolution peripheral blood smear images could be used to detect COVID-19 on a per-patient basis using a novel multiple-instance learning approach. All blood smear images in the study were acquired with the CellaVision DM9600 digital slide scanner. The large, consistent image sets produced by the DM9600 enabled the authors to apply multiple-instance deep learning, aggregating evidence across many cells per patient for COVID-19 screening. The systems uniform imaging geometry also supported interpretability experiments—such as masking cell centers versus edges—to probe where diagnostic signal originated within the scans. The authors concluded that their MIL/DOBA pipeline can screen for COVID-19 with high diagnostic performance (about 79% accuracy and ROC-AUC ≈ 0.90), indicating a genuine morphological association between COVID-19 and blood cells; they also found that performance improved when combining information from both red and white blood cells.

Instrument:
DM9600
Keyword:
COVID19, WBC
Author:
Linko‐Parvinen Anna‐Maria, Keränen Kristiina, Kurvinen Kaisa, Tienhaara Anri
Journal, year:
eJHaem, 2022

Summary: In this study, CellaVision was not the primary analyzer being evaluated but served as a key part of the reference workflow. After running CBC and WBC differentials on the HemoScreen point-of-care device and the Sysmex XN, the lab prepared May–Grünwald-Giemsa blood films and performed a 200-cell manual morphology review; this review was done either by light microscopy or by digital microscopy on a CellaVision DI-60, which provided the digital smear images used to confirm whether abnormal leukocytes were truly present. Using this CellaVision-supported microscopy confirmation as the ground truth, the authors found that HemoScreen’s CBC and five-part differential were highly comparable to Sysmex XN for most parameters and that both systems detected all samples with true leukocyte abnormalities, but HemoScreen produced fewer false abnormal-WBC flags—meaning fewer smears needed CellaVision/manual review.

Instrument:
DI-60
Keyword:
WBC, XN-analyser, hemoscreen, POC, method comparison